Digital Meters
Economic Mutifunction Meter [MFM383A]
| Display Type | LCD with Backlight |
| Display Configuration | 3 Rows of 4 Digits, 1 Row of 7 ½ Digits |
| Electrical Connection | 3¢ - 3W, 3¢ - 4W, 2¢ - 3W, 1¢ - 2W |
| Type of Output | Pulse Output |
| Features | Password Protection, Energy (Active / Reactive / Apparent) |
| Communication Protocol | RS485 and MODBUS RTU |
| CT Primary | 1 / 5A to 10kA (Programmable for Any Value) |
| CT Secondary | 1 / 5A (Programmable) |
| PT Primary | 100V to 10kV (Programmable for Any Value) |
| PT Secondary | 100V to 500V AC (L – L) (Programmable for Any Value) |
| Rated Input Current | Nominal 5A AC (Min - 11mA Max - 6A) |
| Supply Voltage | 100 to 240V AC (-15% to +12%) (45/65Hz) |
| Size | 96 x 96mm |
| Mounting Type | Panel Mount |
| Certification | CE, UL Listed |
Max/Min Demand, Phase Angle Detection [MFM376-230V]
| Display Type | 7 Segment LED Display |
| Display Configuration | 3 Rows of 4 Digits |
| Electrical Connection | 3¢ - 3W, 3¢ - 4W, 2¢ - 3W, 1¢ - 2W |
| Type of Output | Pulse Output |
| Features | Phase Angle Detection, (Max/Min) Demand Power, Run Hour, Auxiliary Interrupts |
| CT Primary | 1 / 5A to 10kA (Programmable for Any Value) |
| CT Secondary | 1 / 5 A (Programmable) |
| PT Primary | 100V to 500kV (Programmable for Any Value) |
| PT Secondary | 100V to 500V (Programmable for Any Value) |
| Rated Input Current | Nominal 5A AC (Min – 14mA, Max – 6A) |
| Supply Voltage | 240V AC (-15% to +12%) (45/65Hz) |
| Size | 96 x 96mm |
| Mounting Type | Panel Mount |
Din Rail, 2 Pulse Outputs, Active/ Reactive Energy, Split Load [MRJ4M-SL]
| Display Type | 7 Segment LED Display |
| Display Configuration | 3 Rows of 4 Digits |
| Electrical Connection | 3Ø - 3W, 3Ø - 4W, 2Ø - 3W, 1Ø - 2W |
| Type of Output | Pulse Output |
| Features | Phase Angle Detection, (Max/Min) Demand Power, Run Hour, Auxiliary Interrupts |
| CT Primary | 1 / 5A to 10kA (Programmable for Any Value) |
| CT Secondary | 1 / 5 A (Programmable) |
| PT Primary | 100V to 500kV (Programmable for Any Value) |
| PT Secondary | 100V to 500V (Programmable for Any Value) |
| Rated Input Current | Nominal 5A AC (Min – 14mA, Max – 6A) |
| Supply Voltage | 240V AC (-15% to +12%) (45/65Hz) |
| Size | 96 x 96mm |
| Mounting Type | Panel Mount |
Analog Meters
0 to 300V,500V,600V Measurement, Size : 96 x 96mm [AM-V-3]
| Pointer | Knife Edge Pointer |
| Pointer Deflection | 0 to 90 degree |
| Scale Characteristics | Non Linear Scale |
| Measuring Voltage Range | 0 to 300V,500V,600V |
| Accuracy | Class 1.5 |
| Frequency | 50/60Hz |
| Certification | CE, RoHS |
Current Transformers
Bus Bar Type Current transformer [SPCT]
| Features | Applicable for bus bar with aperature upto 100mm |
| Rated Primary Rating | 30 to 4000A |
| Rated Secondary Output | 5A |
| Rated Burden (VA) | 1/1.25/1.5/2.5/3/3.75/5/7.5/5/10/15 |
| Accuracy | 0.5/1/3/5 |
| Operating Frequency | AC 50Hz / 60Hz |
| System Voltage | 720V Maximum |
| Mounting | Panel Mount/DIN Rail Mount (Optional Accessory ) |
| Certification | CE |
| Applicable Standard | IEC 61869-2 |